AC/DC Power Supply
TXLN 960 Series, 960 Watt
•
Compact metal case with screw terminal
block
•
•
•
•
Universal input 90-264 VAC
•
•
Compliance to EN 61000-3-2
Active PFC >0.95
E
EMI/EMC compliance with EN
61000-6-3 and EN 61000-6-1
Short circuit, overvoltage and overload
protection
AT
IV
•
•
High efficiency up to 89%
IEC/EN/UL 62368-1 safety approvals
3 year product warranty
The TXLN series is a family of encased power supplies designed for a wide
range of cost critical applications. With a low profile metal case and screw terminal block connection, they are easy to install in any equipment. These power
supplies have universal input and comply with European EMC standards and
the Low Voltage Directive (LVD).
Models
Order Code
Output Power
max.
Output Current
max.
Efficiency
typ.
12 VDC (10.8 - 13.2 VDC)
80'000 mA
87 %
15 VDC (13.5 - 16.5 VDC)
64'000 mA
88 %
24 VDC (21.6 - 26.4 VDC)
40'000 mA
88 %
48 VDC (43.2 - 52.8 VDC)
20'000 mA
89 %
NT
TXLN 960-112
Output Voltage
nom. (adjustable)
TXLN 960-115
TXLN 960-124
960 W
TE
TXLN 960-148
www.tracopower.com
January 22, 2021
Page 1 / 4
TXLN 960 Series, 960 Watt
Input Specifications
Input Voltage
Input Frequency
Input Current
Input Inrush Current
Power Factor
90 - 264 VAC (Full Range)
127 - 375 VDC (Designed for, no certification)
47 - 63 Hz
6'500 mA max.
10'500 mA max.
90 A max.
50 A max.
0.95 min. (Active Power Factor Correction)
0.99 min. (Active Power Factor Correction)
(The need of an external fuse has to be assessed
in the final application.)
- AC Range
- DC Range
- Full Load & Vin = 230 VAC
- Full Load & Vin = 115 VAC
- At 230 VAC
- At 115 VAC
- At 230 VAC
- At 115 VAC
E
Recommended Input Fuse
Output Specifications
Voltage Set Accuracy
Regulation
- Input Variation (Vmin - Vmax)
- Load Variation (0 - 100%)
Ripple and Noise
(20 MHz Bandwidth)
Minimum Load
Hold-up Time
12 VDC model:
15 VDC model:
24 VDC model:
48 VDC model:
- At 230 VAC
- At 115 VAC
- At 230 VAC
NT
Start-up Time
Short Circuit Protection
Overload Protection
Output Current Limitation
Overvoltage Protection
Load Share Function
Load Share Accuracy
±10% (By trim potentiometer)
Output power must not exceed rated power!
±1% max.
0.5% max.
1% max.
150 mVp-p max. (w/ 0.1 µF // 47 µF)
150 mVp-p max. (w/ 0.1 µF // 47 µF)
200 mVp-p max. (w/ 0.1 µF // 47 µF)
250 mVp-p max. (w/ 0.1 µF // 47 µF)
Not required
16 ms min.
16 ms min.
2'000 ms max.
Continuous, Automatic recovery
Constant Current Mode
105 - 135% of Iout max.
115 - 140% of Vout nom.
www.tracopower.com/overview/txln960
10%
AT
IV
Output Voltage Adjustment
- Refer to application note
Safety Specifications
- Certification Documents
TE
Safety Standards
Protection Class
Pollution Degree
Over Voltage Category
www.tracopower.com/overview/txln960
Class I (Prepared): Connection to PE
PD 2
OVC II
EMC Specifications
EMI Emissions
- Conducted Emissions
- Radiated Emissions
- Harmonic Current Emissions
- Voltage Fluctuations & Flicker
EN 61000-6-3 (Generic Residential)
EN 55032 class B (internal filter)
EN 55032 class B (internal filter)
EN 61000-3-2, class D
EN 61000-3-3
All specifications valid at nominal voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
January 22, 2021
Page 2 / 4
TXLN 960 Series, 960 Watt
EMS Immunity
- Electrostatic Discharge
- RF Electromagnetic Field
- EFT (Burst) / Surge
- Conducted RF Disturbances
- PF Magnetic Field
E
- Voltage Dips & Interruptions
EN 55024 (IT Equipment)
Air: EN 61000-4-2, ±8 kV, perf. criteria A
Contact: EN 61000-4-2, ±4 kV, perf. criteria A
EN 61000-4-3, 10 V/m, perf. criteria A
EN 61000-4-4, ±2 kV, perf. criteria A
L to L: EN 61000-4-5, ±2 kV, perf. criteria B
L to PE: EN 61000-4-5, ±4 kV, perf. criteria B
EN 61000-4-6, 10 Vrms, perf. criteria A
Continuous: EN 61000-4-8, 30 A/m, perf. criteria A
1 s: EN 61000-4-8, 300 A/m, perf. criteria A
230 VAC / 50 Hz: EN 61000-4-11
30%, 25 periods, perf. criteria C
>95%, 0.5 periods, perf. criteria B
>95%, 250 periods, perf. criteria C
General Specifications
Power Derating
Over Temperature
Protection Switch Off
Cooling System
Standby Power Source
- Operating Temperature
- Storage Temperature
- High Temperature
- Low Input Voltage
- Protection Mode
- Output Voltage
- Output Current
- Voltage Controlled Remote
NT
Remote Control
Altitude During Operation
90% max. (non condensing)
–20°C to +70°C
–40°C to +85°C
2.5 %/K above 50°C
See application note: www.tracopower.com/overview/txln960
90°C min. / 95°C typ. / 100°C max. (Automatic
recovery)
Forced air cooling (with internal fan)
12 VDC
300 mA max.
(Only for remote control)
See application note: www.tracopower.com/overview/txln960
4'000 m max. (The ambient temperature has to
be derated by 5 K / 1000 m when operated
above 2000 m)
105 kHz typ. (PWM)
Reinforced Insulation
3'000 VAC
1'800 VAC
500 VAC
100 MΩ min.
1500 µA max.
AT
IV
Relative Humidity
Temperature Ranges
Switching Frequency
Insulation System
Isolation Test Voltage
- Calculated MTBF
TE
Isolation Resistance
Leakage Current
(at 264 VAC / 60Hz)
Reliability
Housing Material
Connection Type
Weight
- Input to Output, 60 s
- Input to Case or PE, 60 s
- Output to Case or PE, 60 s
- Input to Output, 500 VDC
- Touch Current
Power OK Signal
84'170 h
Aluminium
Screw Terminal
2500 g
Voltage source output
High level
Low level
(Refers to 'PG' and 'GND' Pin)
Indicated by green LED
- Power OK
- Power Off
Status Indicator
Sense Function
Environmental Compliance - REACH Declaration
www.tracopower.com/info/reach-declaration.pdf
REACH SVHC list compliant
REACH Annex XVII compliant
www.tracopower.com/info/rohs-declaration.pdf
Exemptions: 6a, 6b, 6c, 7a, 7c-I, 7c-II
- RoHS Declaration
All specifications valid at nominal voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
January 22, 2021
Page 3 / 4
TXLN 960 Series, 960 Watt
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/txln960
Outline Dimensions
220
15
8.5
40
20
Input
34.5
2-M4
4-M3-P0.5
Output
CN1
CN11
275
30
240
Function
Pin
Function
1
AC (L)
1-3
+Vout
2
AC (N)
4-6
–Vout
3
FG
5
16.5
30
16.5
2-M3-P0.5
6
240
29
6
Vadj
6
5
29
7.5
34
Pin
4
5
6
6
6
4-M3-P0.5
7.5
L N
1
2
3
63
220
16
13
20
210
40
Dimensions in mm
Tolerances:
0 – 8: ±0.2
8 – 25: ±0.3
25 – 80: ±0.5
80 – 250: ±0.8
Pin
Function
1
CS
2
PG
3
+Sense
4
–Sense
5
–Remote
6
+Remote
7
Standby
8
GND
CN11:
6 pin, 11 mm pitch
CN3:
HRS DF11-8DP-2DSA
TE
NT
25
30
12.5
2-M4
CN1:
3 pin, 10mm pitch
with PC cover
CN3
4-M3-P0.5
PG
RSRC2
GND
39
Auxiliary
AT
IV
CS
RS+
RC1
AUX
2-M3-P0.5
E
3
113
125
110
2
113
1
+v +v +v -v -v -v
4-M3-P0.5
© Copyright 2020 Traco Electronic AG
Specifications can be changed without notice.
www.tracopower.com
Rev. January 22, 2021
Page 4 / 4