TXLN 960-148

TXLN 960-148

  • 厂商:

    TRACOPOWER

  • 封装:

  • 描述:

    封闭式 AC DC 转换器 1 输出 48V 90 ~ 264 VAC,127 ~ 375 VDC 输入

  • 数据手册
  • 价格&库存
TXLN 960-148 数据手册
AC/DC Power Supply TXLN 960 Series, 960 Watt • Compact metal case with screw terminal block • • • • Universal input 90-264 VAC • • Compliance to EN 61000-3-2 Active PFC >0.95 E EMI/EMC compliance with EN 61000-6-3 and EN 61000-6-1 Short circuit, overvoltage and overload protection AT IV • • High efficiency up to 89% IEC/EN/UL 62368-1 safety approvals 3 year product warranty The TXLN series is a family of encased power supplies designed for a wide range of cost critical applications. With a low profile metal case and screw terminal block connection, they are easy to install in any equipment. These power supplies have universal input and comply with European EMC standards and the Low Voltage Directive (LVD). Models Order Code Output Power max. Output Current max. Efficiency typ. 12 VDC (10.8 - 13.2 VDC) 80'000 mA 87 % 15 VDC (13.5 - 16.5 VDC) 64'000 mA 88 % 24 VDC (21.6 - 26.4 VDC) 40'000 mA 88 % 48 VDC (43.2 - 52.8 VDC) 20'000 mA 89 % NT TXLN 960-112 Output Voltage nom. (adjustable) TXLN 960-115 TXLN 960-124 960 W TE TXLN 960-148 www.tracopower.com January 22, 2021 Page 1 / 4 TXLN 960 Series, 960 Watt Input Specifications Input Voltage Input Frequency Input Current Input Inrush Current Power Factor 90 - 264 VAC (Full Range) 127 - 375 VDC (Designed for, no certification) 47 - 63 Hz 6'500 mA max. 10'500 mA max. 90 A max. 50 A max. 0.95 min. (Active Power Factor Correction) 0.99 min. (Active Power Factor Correction) (The need of an external fuse has to be assessed in the final application.) - AC Range - DC Range - Full Load & Vin = 230 VAC - Full Load & Vin = 115 VAC - At 230 VAC - At 115 VAC - At 230 VAC - At 115 VAC E Recommended Input Fuse Output Specifications Voltage Set Accuracy Regulation - Input Variation (Vmin - Vmax) - Load Variation (0 - 100%) Ripple and Noise (20 MHz Bandwidth) Minimum Load Hold-up Time 12 VDC model: 15 VDC model: 24 VDC model: 48 VDC model: - At 230 VAC - At 115 VAC - At 230 VAC NT Start-up Time Short Circuit Protection Overload Protection Output Current Limitation Overvoltage Protection Load Share Function Load Share Accuracy ±10% (By trim potentiometer) Output power must not exceed rated power! ±1% max. 0.5% max. 1% max. 150 mVp-p max. (w/ 0.1 µF // 47 µF) 150 mVp-p max. (w/ 0.1 µF // 47 µF) 200 mVp-p max. (w/ 0.1 µF // 47 µF) 250 mVp-p max. (w/ 0.1 µF // 47 µF) Not required 16 ms min. 16 ms min. 2'000 ms max. Continuous, Automatic recovery Constant Current Mode 105 - 135% of Iout max. 115 - 140% of Vout nom. www.tracopower.com/overview/txln960 10% AT IV Output Voltage Adjustment - Refer to application note Safety Specifications - Certification Documents TE Safety Standards Protection Class Pollution Degree Over Voltage Category www.tracopower.com/overview/txln960 Class I (Prepared): Connection to PE PD 2 OVC II EMC Specifications EMI Emissions - Conducted Emissions - Radiated Emissions - Harmonic Current Emissions - Voltage Fluctuations & Flicker EN 61000-6-3 (Generic Residential) EN 55032 class B (internal filter) EN 55032 class B (internal filter) EN 61000-3-2, class D EN 61000-3-3 All specifications valid at nominal voltage, full load and +25°C after warm-up time unless otherwise stated. www.tracopower.com January 22, 2021 Page 2 / 4 TXLN 960 Series, 960 Watt EMS Immunity - Electrostatic Discharge - RF Electromagnetic Field - EFT (Burst) / Surge - Conducted RF Disturbances - PF Magnetic Field E - Voltage Dips & Interruptions EN 55024 (IT Equipment) Air: EN 61000-4-2, ±8 kV, perf. criteria A Contact: EN 61000-4-2, ±4 kV, perf. criteria A EN 61000-4-3, 10 V/m, perf. criteria A EN 61000-4-4, ±2 kV, perf. criteria A L to L: EN 61000-4-5, ±2 kV, perf. criteria B L to PE: EN 61000-4-5, ±4 kV, perf. criteria B EN 61000-4-6, 10 Vrms, perf. criteria A Continuous: EN 61000-4-8, 30 A/m, perf. criteria A 1 s: EN 61000-4-8, 300 A/m, perf. criteria A 230 VAC / 50 Hz: EN 61000-4-11 30%, 25 periods, perf. criteria C >95%, 0.5 periods, perf. criteria B >95%, 250 periods, perf. criteria C General Specifications Power Derating Over Temperature Protection Switch Off Cooling System Standby Power Source - Operating Temperature - Storage Temperature - High Temperature - Low Input Voltage - Protection Mode - Output Voltage - Output Current - Voltage Controlled Remote NT Remote Control Altitude During Operation 90% max. (non condensing) –20°C to +70°C –40°C to +85°C 2.5 %/K above 50°C See application note: www.tracopower.com/overview/txln960 90°C min. / 95°C typ. / 100°C max. (Automatic recovery) Forced air cooling (with internal fan) 12 VDC 300 mA max. (Only for remote control) See application note: www.tracopower.com/overview/txln960 4'000 m max. (The ambient temperature has to be derated by 5 K / 1000 m when operated above 2000 m) 105 kHz typ. (PWM) Reinforced Insulation 3'000 VAC 1'800 VAC 500 VAC 100 MΩ min. 1500 µA max. AT IV Relative Humidity Temperature Ranges Switching Frequency Insulation System Isolation Test Voltage - Calculated MTBF TE Isolation Resistance Leakage Current (at 264 VAC / 60Hz) Reliability Housing Material Connection Type Weight - Input to Output, 60 s - Input to Case or PE, 60 s - Output to Case or PE, 60 s - Input to Output, 500 VDC - Touch Current Power OK Signal 84'170 h Aluminium Screw Terminal 2500 g Voltage source output High level Low level (Refers to 'PG' and 'GND' Pin) Indicated by green LED - Power OK - Power Off Status Indicator Sense Function Environmental Compliance - REACH Declaration www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant www.tracopower.com/info/rohs-declaration.pdf Exemptions: 6a, 6b, 6c, 7a, 7c-I, 7c-II - RoHS Declaration All specifications valid at nominal voltage, full load and +25°C after warm-up time unless otherwise stated. www.tracopower.com January 22, 2021 Page 3 / 4 TXLN 960 Series, 960 Watt Supporting Documents Overview Link (for additional Documents) www.tracopower.com/overview/txln960 Outline Dimensions 220 15 8.5 40 20 Input 34.5 2-M4 4-M3-P0.5 Output CN1 CN11 275 30 240 Function Pin Function 1 AC (L) 1-3 +Vout 2 AC (N) 4-6 –Vout 3 FG 5 16.5 30 16.5 2-M3-P0.5 6 240 29 6 Vadj 6 5 29 7.5 34 Pin 4 5 6 6 6 4-M3-P0.5 7.5 L N 1 2 3 63 220 16 13 20 210 40 Dimensions in mm Tolerances: 0 – 8: ±0.2 8 – 25: ±0.3 25 – 80: ±0.5 80 – 250: ±0.8 Pin Function 1 CS 2 PG 3 +Sense 4 –Sense 5 –Remote 6 +Remote 7 Standby 8 GND CN11: 6 pin, 11 mm pitch CN3: HRS DF11-8DP-2DSA TE NT 25 30 12.5 2-M4 CN1: 3 pin, 10mm pitch with PC cover CN3 4-M3-P0.5 PG RSRC2 GND 39 Auxiliary AT IV CS RS+ RC1 AUX 2-M3-P0.5 E 3 113 125 110 2 113 1 +v +v +v -v -v -v 4-M3-P0.5 © Copyright 2020 Traco Electronic AG Specifications can be changed without notice. www.tracopower.com Rev. January 22, 2021 Page 4 / 4
TXLN 960-148 价格&库存

很抱歉,暂时无法提供与“TXLN 960-148”相匹配的价格&库存,您可以联系我们找货

免费人工找货